Laboratory Equipment

Our range of products include vertical laboratory autoclave, digital turbidity meter, flow cup viscometer, food freeze dryer and ph meter 3 point.

Vertical Laboratory Autoclave

Request Callback

₹ 49500 / Piece Get Latest Price

Product Brochure
Chamber Volume22 L
Capacity (in Litre)22 L
Mount TypeVertical
OrientationVertical
Automation GradeSemi Automatic
Automation LevelSemi-Automatic
Chamber MaterialStainless Steel 304
Max Temperature134 C
ShapeCylindrical
Heating ModeSteam Heated
Control TypePID Controller
Door TypeSingle Door
Power Supply230 V AC
Power Consumption5 KW
Lid TypeRadial Lock
FeaturesDoor Safety Lock, Pressure Control, Radial Lock, Low Water Cut-off, Digital Timer
Vacuum PumpSingle Stage

Minimum order quantity: 1 Piece


  • Vertical Autoclave widely used in Microbiology, Medicine, Waste treatment, Pharma
  • QC / QA / R & D and all applications requiring sterilization.
  • Double walled construction with Inner chamber (boiler) made of Stainless Steel 16 SWG sheet – 304 grade and Outer shell of Stainless-Steel sheet - 304 grade, mirror polish.
  • Temperature Range: 121°C to 125°C
  • Temperature Resolution: 0.1°C
  • Pressure range: 15 PSI to 20 PSI. (Factory Set at 15 PSI.)
  • The Boiler and outer shell is provided with air insulation.
  • All internal joints argon arc welded.
  • Lid is made of die pressed Thick Stainless Steel plate & is equipped with Pressure gauge, Steam release/Exhaust valve & spring loaded safety valves & ¼” BSP Port fitted with coupling for validation purpose.
  • Foot lifting arrangement for the lid.
  • Drain Valve facilitate easy cleaning of the chamber.
  • Fully Argon welded to avoid steam and pressure leakage.
  • Heavy duty industrial flange heaters.
  • Full sterilization cycle including Air purging, Sterilizing hold time, Cycle end with release/exhaust of pressure & alarm is automatic.
  • Microprocessor based Controller with time and temperature programmable by user.
  • Timer Range: 1- 99 Minutes.
  • Temperature Sensor: PT-100.
  • Low water level alarm with heater cut off.
  • Perforated basket made of Stainless Steel sheet – 304 grade.
  • Operates on 230 Volts AC Single phase 50 Hz.

Size (Dia. x Height) 

Capacity (Liters) 

Rating Watts

Inch

Cm

12 Ø x 20 Ht

30 Ø x 50 Ht

40

2000

14 Ø x 22 Ht

35 Ø x 55 Ht

52

3000

16 Ø x 24 Ht

40 Ø x 60 Ht

80

4000

18 Ø x 24 Ht

45 Ø x 60 Ht

98

4000

18 Ø x 30 Ht

45 Ø x 75 Ht

120

5000

22 Ø x 30 Ht

55 Ø x 75 Ht

152

6000

22 Ø x 36 Ht

55 Ø x 90 Ht

200

7000

 

 

Digital Turbidity Meter

Request Callback

₹ 17500 / Piece Get Latest Price

Product Brochure
Turbidity Range0 to 1000 NTU
Light SourceLED
Mounting TypeBenchtop
Display TypeLED
Accuracy+ or - 3 Percent
Power SourceAC Adapter
BrandHanna
Standards UsedFormazin
Measurement UnitsNTU
Data LoggingYes

Minimum order quantity: 1 Piece

Turbidity Range 0 to 1000 NTU
Light Source Tungsten Lamp
Mounting Type Benchtop
Usage/Application Industrial
Display Type 31/2 digit LED
Accuracy +/- 3% OF FULL SCALE DEFLECTION IN 0-1000 JTU/NTU
Measure Range 0-1000 JTU/NTU
Brand VSI
Model Name/Number Digital Turbidity Meter VSI-13
Model VSI-13
Application Laboratory, Industrial
Warranty 1 Year
Resolution 1 NTU/JTU
Number Of Ranges Two
Power 230V +/- 10%, 50Hz AC with Built-in Voltage Stabilizer.
Country of Origin Made in India
Availability In Stock

We are one of the leading manufacturers of Digital Turbidity Meters/Analyzers. The Digital Turbidity Meter (VSI-13) is very accurate & stable instrument for measurement of turbidity upto 1000 NTU/JTU.

Features of Digital Turbidity Meter/Turbidity Analyzer:

  • Measurement Upto1000 NTU/JTU
  • Sewage & Drinking Water Testing
  • Highly Stable, Reliable & Accurate Results
  • 3 1/2 Digit LED Display
  • Simple & Easy to Use.
Technical Specifications of Digital Turbidity Meter/Turbidity Analyzer : VSI-13

Range

0 to 1000 NTU/JTU in 2 Ranges

Display

3 1/2 digit LED

Accuracy

- 3% Full Scale - 1digit

Resolution

1 NTU/JTU

Detector

Photo diode

Light Source

6.8 V, 250 mA Lamp

Sample System

30 mm. dia Clear Glass Test Tubes

Calibration

With Formazine Solution

Power Supply

230V -10%, 50 Hz AC with built-in Voltage Stabilizer

Standard Accessories

One Set of 3 Glass Test Tubes of 30 mm. Dia & Instruction Manual.

Flow Cup Viscometer

Request Callback

₹ 2950 / Piece Get Latest Price

Product Brochure
Cup StandardB4
Cup NumberNo. 4
MaterialBrass
Orifice Diameter4 mm
Stand IncludedWith Stand
StandardIS 3944, ASTM D1200
Capacity100 mL
ApplicationPaint
FinishPolished

Minimum order quantity: 1 Piece

Usage/Application Laboratory
Weight 350 gm
Material Plastic, Stainless Steel
Height 3 ft
Country of Origin Made in India
Packaging Type Box
Operating Mode Manual
Availability In Stock
Flow Cup Viscometers provide kinematics viscosity data. The measured kinematics
viscosity is generally expressed in seconds (s) flow time when the fluid is flowing
through an orifice at a specified temperature. Thanks to the conversion equations the viscosity is calculated from the flow time to centistokes (cSt). The calibration certificates are supplied with the cups. According to the standards, there are several viscosity ranges available from 5 cSt.
Flow cups made of anodized aluminium body with a stainless steel orifice. Ensuring the accuracy of the test results,You can check the viscosity results using the standard oils specially manufactured for these kind of viscometers (available under request),
or sending the instrument to our calibration laboratories. Industries like paint, ink, varnishes and similar products use this very easy to use flow cups to quickly calculate the viscosity. Code Model Bore Viscosity range
mm (cStCode) 

Food Freeze Dryer

Request Callback

₹ 385000 / Piece Get Latest Price

Product Brochure
Application TypeFood Industry
Mounting TypeCabinet
Number of DoorsSingle
Capacity8 L
Temperature Range-40 degree c
BrandVGS
Power5 kW
Voltage220 V
MaterialStainless Steel
Frequency50-60 Hz

Minimum order quantity: 1 Piece

Food Freeze Dryer (8kg /-40⁰C)

Food Freeze Dryer is a device that uses Vacuum Drying Technology to remove moisture from the Food, which can extend the shelf life while remaining nutrients, Flavor and appearance.

Freeze drying is a process whereby water or other solvent is removed from frozen materials by converting the frozen water directly into vapour without the intermediate formation of liquid water. The basis for this sublimation process involves the absorption of heat by the frozen sample in order to vaporize the ice; the use of a vacuum pump to enhance the removal of water vapor from the surface of the sample; the transfer of water vapor to a collector; and the removal of heat by the collector in order to condense the water vapor. In essence, the freeze dry process is a balance between the heat absorbed by the sample to vaporize the ice and the heat removed from the collector to convert the water vapor into ice

 

7" Touch Screen Display

SS304 Tray

Graph can view

Password Protection

Easy to move with wheels, locking wheels for stability

Quick Mode, Professional Mode, Frozen Mode, Defrost Mode

Vacuum Pump (DSVP66) as a Standard Supply

Temperature Range is -40°C

System can store data of 10recipes

Transparent Acrylic door for easy view

Ph Meter 3 Point

Request Callback

₹ 21000 / Piece Get Latest Price

Product Brochure
Meter TypeBenchtop
pH Range-2 to 16 pH
Accuracy±0.01 pH
Calibration Points3 point
ChannelsMulti Channel
Temperature CompManual
Data LoggingUSB Output
Display TypeBacklit LCD
Power Source230 V AC
BrandOther Brand
UsageLaboratory

Minimum order quantity: 1 Piece

SALIENT FEATURES

During the pH mode, up to 3 points push-button calibration with auto- buffer recognition. (USA & NIST Buffer)

Selectable pH buffer standards and temperature units.

Automatically Electrode diagnosis shows the pH slope and offset.

Automatic Temperature Compensation (ATC) ensures highly accurate measurement over the entire range.

Automatic endpoint function freezes the stable measured values.

Help message as an operational guide to help & understand how to use meter.

Setup menu allows setting pH Buffer set, number of calibration point, temperature, unit etc. user customizes buffer standards, calibration points, stability conditions, resolution, temperature units, date and time to meet measurement requirements.

Reset function can resumes all settings to factory default values.

Expanded memory stores and recalls up to 100 readings.

USB Interface

X

Contact Us

Mrs. Vanaja (Marketing Sales Coordinator)
Test Instrumentation
1 ST Floor, Door No 150, Kamarajar Road, Varatharajapuram , Singanallur
Coimbatore - 641005, Tamil Nadu, India

Send Email
Share: